Eutech Electrodes and Solutions
Eutech Conductivity Solutions
Product Brochure
Packaging Size | 480 ML BOTTLE |
Buffer Value | 84, 100, 500, 1413, 1288, 2764, 1118, 5000 |
Usage/Application | Laboratory |
Brand | Eutech |
CERTIFICATE | COA Available |
colour | colourless |
Calibration Solutions For Conductivity
Conductivity Solutions ( 480 ml)
Supplied in a card board packing with Certificate of Analysis
Order Code |
Description |
ECCON84BT |
84 mS KCL (480 ml) |
ECCON100BT |
100 mS KCL (480 ml) |
ECCON500BT |
500 mS KCL (480 ml) |
ECCON1413BT |
1413 mS KCL (480 ml) |
ECCON2764BT |
2764 mS KCL (480 ml) |
ECCON5000BT |
5.0 mS KCL (480 ml) |
ECCON1288BT |
12.88 mS KCL (480 ml) |
ECCON1118BT |
111.8 mS KCL (480 ml) |
Eutech PH Buffer Solutions
Product Brochure
Packaging Size | 480 ML BOTTLE |
Buffer Value | 4, 7, 10, 12.45, 1.68, 9.18, 6.86 pH |
Usage/Application | Laboratory |
Brand | Eutech |
SHELF LIFE | MORE THAN 2 YEARS |
CERTIFICATE | COA available |
CALIBRATION SOLUTIONS
Calibration Solution Bottles ( 480 ml )
Supplied in a card board packing with Certificate of Analysis
Order Code | Description |
ECBU1BT | pH 1.68 Buffer Solution (480 ml)
|
ECBU4BTC | pH 4.01 Buffer Solution (480 ml) |
ECBU686BT | pH 6.86 Buffer Solution (480 ml) |
ECBU7BTC | pH 7.00 Buffer Solution (480 ml) |
ECBU9BT | pH 9.00 Buffer Solution (480 ml) |
ECBU918BT | pH 9.18 Buffer Solution (480 ml) |
ECBU10BTC | pH 10.01 Buffer Solution (480 ml) |
ECBU12BT | pH 12.45 Buffer Solution (480 ml) |
Eutech Electrode- ECFC7252101B
Product Brochure
Model Name/Number | ECFC7252101B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 1-13 |
Material | Plastic body |
Warranty | 6 months |
PLASTIC COMBINATION pH ELECTRODE
Specifications | ECFC7252101B |
Body | Plastic-body |
pH Range | 1 to 13 pH |
Operating Temperature | 0 to 80 0C |
Electrode Type | Combination |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl, Sealed |
Reference Junction | Single |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 90 x 12mm |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
*Electrode supplied with standard cable length of 1m and with BNC connector.
Eutech Electrode- ECFC7352901B
Product Brochure
Model Name/Number | ECFC7352901B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 1-13 |
Material | Plastic body |
Warranty | 6 months |
pH Electrode
ECFC73529 is a “ 3 in 1” pH electrode with in built temp.sensor. It has an unbreakable plastic body, which offers a high level of chemical resistance.
Specifications | ECFC7352901B |
Body | Plastic-body |
pH Range | 1 to 13 pH |
Operating Temperature | 0 to 80 0C |
Electrode Type | Combination |
In Built Temp. Sensor | Yes |
Reference Element | Ag/AgCl ,Sealed |
Reference Junction | Single |
Standard Termination | 1 meter cable with BNC & 2.5 phono |
Length & Diameter | 90 x 12mm |
Application
“ 3 in 1” pH electrode with in built temp.sensor .General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
Eutech Electrode- ECFG7350401B
Product Brochure
Model Name/Number | ECFG7350401B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-13 |
Material | Glass body |
Warranty | 6 months |
pH Electrode
ECFG73504 is a glass body combination electrode, which is suitable for measurements in high temperature range up to 1000 Centigrade.
Specifications | ECFG7350401B |
Body | Glass |
pH Range | 0 to 13 pH |
Operating Temperature | 0 to 100 0C |
Electrode Type | Combination |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl ,Refillable |
Reference Junction | Single |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 130 x 12mm |
Order Code | ECFG7350401B |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
Eutech Electrode- ECFG6351101B
Product Brochure
Model Name/Number | ECFG6351101B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-13 |
Material | Glass body |
Warranty | 6 months |
GLASS BODY COMBINATION pH ELECTRODE
Specifications | ECFG6351101B |
Body | Glass |
pH Range | 0 to 13 pH |
Operating Temperature | 0 to 100 0C |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl ,Sealed |
Reference Junction | Single |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 55 x 8 mm |
Application
- Solid or semi-solid samples such as cheese, meats, fruits, bread, or other similar sample.
*Electrode supplied with standard cable length of 1m and with BNC connector.
Eutech Electrode- ECFG7252001B
Product Brochure
Model Name/Number | ECFG7252001B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-12 |
Material | Glass body |
Warranty | 6 months |
Glass Body Combination pH Electrode
Specifications | ECFG7252001B |
Body | Glass |
pH Range | 0 to 12 pH |
Operating Temperature | 0 to 100 0C |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl Refillable |
Reference Junction | Single |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 110 x 12 mm |
Application
- Surface measurements such as paper, skin, textile, leather and agar plates.
*Electrode supplied with standard cable length of 1m and with BNC connector
Eutech Electrode- ECFG7370101B
Product Brochure
Model Name/Number | ECFG7370101B |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-13 |
Material | Glass body |
Warranty | 6 months |
GLASS BODY COMBINATION pH ELECTRODE
Specifications | ECFG7370101B |
Body | Glass |
pH Range | 0 to 13 pH |
Operating Temperature | 0 to 100 0C |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl Refillable |
Reference Junction | Double |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 110 x 12 mm |
Application
Clog free double-junction glass pH electrode, ideal for samples containing TRIS buffers, sulfides and more.
Eutech Electrode- EC620130
Product Brochure
Model Name/Number | EC620130 |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-14 |
Material | Glass body |
Warranty | 6 months |
GLASS BODY COMBINATION PH ELECTRODE
Specifications | EC620130 |
Body | Glass |
pH Range | 0 to 14 pH |
Operating Temperature | 0 to 80 0C |
In Built Temp. Sensor | No |
Reference Element | Ag/AgCl ,Refillable, Open pore |
Reference Junction | Double |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 140 x 12 mm |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
- Reference contamination problems which require a double junction reference, such as media containing sulfides, bromides, iodides and cyanides.
- Tris buffers, clinical, and biological media containing proteins, creams, fats and cosmetics.
- Low ionic strength solutions, such as high purity water.
- Research measurements, fruit juices, beer, milk and yogurt.
- Soil pH measurements.
- Swimming pool, pH control under continuous flow conditions.
*Electrode supplied with standard cable length of 1m and with BNC connector.
Eutech Electrode- EC620131
Product Brochure
Model Name/Number | EC620131 |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-14 |
Material | Glass body |
Warranty | 6 months |
GLASS BODY COMBINATION pH ELECTRODE
Specifications | EC620131 |
Body | Glass |
pH Range | 0 to 14 pH |
Operating Temperature | 0 to 80 0C |
In Built Temp. Sensor | No |
Reference Element | Polymer –gel Sealed, Open pore |
Reference Junction | Double |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 120 x 12 mm |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
- High viscosity solutions such as emulsions, suspensions, paints and varnishes where frequent cleaning of the reference is necessary.
- Portable pH meter; field and school use.
- Reference contamination problems which require a double junction reference, such as media containing sulfides, bromides, iodides,and cyanides.
- Tris buffers, clinical, and biological media containing proteins, creams, fats and cosmetics.
- Research measurements, fruit juices, beer, milk and yogurt.
- Soil pH measurements.
- Paper and pulp
*Electrode supplied with standard cable length of 1m and with BNC connector.
Eutech Electrode- EC620132
Product Brochure
Model Name/Number | EC620132 |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 0-14 |
Material | Plastic body |
Warranty | 6 months |
PLASTIC COMBINATION pH ELECTRODE
Specifications | EC620132 |
Body | Plastic -body |
pH Range | 0 to 14 pH |
Operating Temperature | 0 to 60 0C |
In Built Temp. Sensor | No |
Reference Element | Polymer –gel Sealed, open pore |
Reference Junction | Double |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 105 x 12 mm |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
- Tris buffers, clinical, and biological media containing proteins, creams, fats and cosmetics.
- Low ionic strength solutions, such as high purity water.
- Reference contamination problems which require a double junction reference, such as media containing sulfides, bromides, iodides,and cyanides.
*Electrode supplied with standard cable length of 1m and with BNC connectors
Eutech Electrode- EC620133
Product Brochure
Model Name/Number | EC620133 |
Brand | Eutech |
Usage/Application | Laboratory |
Ph Range | 2-11 |
Material | Glass body |
Warranty | 6 months |
PLASTIC COMBINATION pH ELECTRODE
Specifications | EC620133 |
Body | Glass -body |
pH Range | 2 to 11 pH |
Operating Temperature | 0 to 50 0C |
In Built Temp. Sensor | No |
Reference Element | Polymer –gel Sealed, open pore |
Reference Junction | Double |
Standard Termination | 1 meter cable with BNC |
Length & Diameter | 80 x 6 mm |
Application
- General purpose, aqueous pH measurements. Quality control, general laboratory and aquarium water.
- Tris buffers, clinical, and biological media containing proteins, creams, fats and cosmetics.
- Surface measurements such as paper, skin, textile, leather and agar plates.
- Reference contamination problems which require a double junction reference, such as media containing sulfides, bromides, iodides,and cyanides.
- Soil pH measurements.
*Electrode supplied with standard cable length of 1m and with BNC connectors
Eutech TDS Solutions
Product Brochure
Model Name/Number | TDS calibration standard |
Brand | EUTECH |
Usage/Application | Calibration |
Buffer Value | 50, 300, 1000, 3000 PPM |
Capacity | 480 ml |
colour | colour less |
TDS Calibration Solutions ( 480 ml)
Supplied in a card board packing with Certificate of Analysis
Order Code |
Description |
EC44250BT |
50 ppm (480 ml) |
EC442300BT |
300 ppm (480 ml) |
EC4421000BT |
1000 ppm (480 ml) |
EC4423000BT |
3000 ppm (480 ml) |
Eutech ORP Calibration Standards
Product Brochure
Value of ORP | 475, 263, 86 mV |
SHELF LIFE | MORE THAN 2 YEARS |
COLOUR | COLOUR LESS |
Certificate | COA Avaiable |
Brand | Eutech |
Capacity | 480 ml bottle |
ORP Calibration Solutions (480 ml per bottle )
Supplied in a card board packing with Certificate of Analysis
Order Code | Description |
ECORPPRE | Pretreatment solution (475mV) (480 ml) |
ECORPQUIN | Quinhydrone 263 (263) mV, ±15mV to ±30mV @25 0C (480 ml) |
ECORPQUIN086 | Quinhydrone 86 ( 86 mV) (480 ml) |
Eutech Salinity Calibration Standards
Product Brochure
Value of salinity | 5, 25, 45ppt |
SHELF LIFE | more than 2 years |
capacity | 480 ml bottle |
Brand | Eutech |
certification | COA Available |
colour | colourless |
Salinity Calibration Solutions
Supplied in a card board packing with Certificate of Analysis
Order Code | Description |
ECNACL5PPT | 5 ppt*Nacl calibration solution |
ECNACL25PPT | 25 ppt*Nacl calibration solution |
ECNACL45PPT | 45 ppt*Nacl calibration solution |
*480 ml solution bottle